![coleman saluspa error codes e03 coleman saluspa error codes e03](https://i.ytimg.com/vi/Di6t1YFmwqA/maxresdefault.jpg)
it will cause the E3 and the High Limit Breaker to trip. If the water temperature added to the Hot Tub and PCU was over 116 F. If this is the cause then drain the hot water and add cold water enough to lower the temperature below 104 F. Filling the Hot Tub directly from the Household Hot Water system could potentially reach this temperature.
![coleman saluspa error codes e03 coleman saluspa error codes e03](https://i5.walmartimages.com/asr/54d551fa-14d0-4319-b6ef-b7546fe7d7dd_1.6ff5dbc2ab9e0db2228c5143ee798c48.jpeg)
This will cause Faults and Performance issues with the PCU.Īnother possible cause is the temperature of the water in the Hot Tub has reached 113 F.
![coleman saluspa error codes e03 coleman saluspa error codes e03](https://img1.wynimg.com/static/Resorts/Assets/8737O08L.jpg)
The Pipe should be straight and not kinked or collapsed.ĭo Not Block or Restrict the Flow of the Intake or Discharge Ports located inside the Hot Tub. Check the Piping from the Discharge Port on the PCU to the Discharge Port on the Hot Tub, make sure it is straight and not kinked.īe sure the Cover Cap has been removed and check the Discharge Port for obstructions in the openings.Ĭheck the Piping from the Heater Discharge Port to the Hot Tub. Check the Discharge Port in the Hot Tub for obstructions in the openings and make sure the Clear Cap has been removed.
COLEMAN SALUSPA ERROR CODES E03 CODE
This will reset the PCU, if the error code returns then you will need to follow the corrective steps for that code.Ī possible cause can be a restriction in the flow from the Discharge of the PCU. Anytime an error code appears first perform the PCU RESET - Plug in the GFCI - then Press the TEST BUTTON on the GFCI - wait 5 seconds -then press the RESET BUTTON. E3 will disable all functions and requires the PCU to be Reset (see solution) to clear once the temperature is within safe use range.ĭue to the sensitive nature of the sensors and control electronics it is possible that the error code was triggered by a surge in the supply power, a momentary loss of supply power or even the effect of lightning. 45 C.) within the PCU before the water has passed through the Heater. The E3 Error indicates a condition where the Temperature Sensor has sensed a high temperature (Greater than 113 F. Modified on: Thu, 14 Mar, 2019 at 9:39 AM
COLEMAN SALUSPA ERROR CODES E03 PORTABLE
Solution home Service Solutions Portable Spas PCU E3 Error Code